Technology Archives | Synaptek-DLS https://synapteklabs.com/category/technology/ Deep Learning Science Sat, 16 Jul 2022 14:46:12 +0000 en-GB hourly 1 https://wordpress.org/?v=6.6.1 https://synapteklabs.com/wp-content/uploads/2021/04/fav2-50x50.png Technology Archives | Synaptek-DLS https://synapteklabs.com/category/technology/ 32 32 Raman Spectroscopy https://synapteklabs.com/raman-spectroscopy-has-answers/ https://synapteklabs.com/raman-spectroscopy-has-answers/#respond Wed, 13 Jul 2022 22:36:23 +0000 https://synapteklabs.com/?p=2766 The ultimate research-grade confocal Raman microscope delivers outstanding performance and the best data in the shortest time. Made for experts who demand fast and accurate data.

The post Raman Spectroscopy appeared first on Synaptek-DLS.

]]>
Raman Spectroscopy Has The Answers We Need

inVia™ confocal Raman spectroscopy microscope

Provides Structural Fingerprints

Raman spectroscopy is commonly used in chemistry to provide a structural fingerprint by which molecules can be identified. Most people will never have to completely know or understand how this all works. The article will just cover very basic information.

Raman spectroscopy is a spectroscopic technique typically used to determine vibrational modes of molecules, although rotational and other low-frequency modes of systems may also be observed.

It relies upon inelastic scattering of photons, known as Raman scattering. A source of monochromatic light, usually from a laser in the visible, near-infrared, or near ultraviolet range is used, although X-rays can also be used.

Lasers and Photons

The laser light interacts with molecular vibrations, phonons, or other excitations in the system, resulting in the energy of the laser photons being shifted up or down.

The shift in energy gives information about the vibrational modes in the system. Infrared spectroscopy typically yields similar yet complementary information.

Typically, a sample is illuminated with a laser beam. Electromagnetic radiation from the illuminated spot is collected with a lens and sent through a monochromator.

Elastic scattered radiation at the wavelength corresponding to the laser line (Rayleigh scattering) is filtered out by either a notch filter, edge pass filter, or a band pass filter, while the rest of the collected light is dispersed onto a detector.

Collecting Raman Spectra

Spontaneous Raman scattering is typically very weak; as a result, for many years the main difficulty in collecting Raman spectra was separating the weak inelastically scattered light from the intense Rayleigh scattered laser light (referred to as “laser rejection”).

Historically, Raman spectrometers used holographic gratings and multiple dispersion stages to achieve a high degree of laser rejection. In the past, photomultipliers were the detectors of choice for dispersive Raman setups, which resulted in long acquisition times.

However, modern instrumentation almost universally employs notch or edge filters for laser rejection. Dispersive single-stage spectrographs (axial transmissive (AT) or Czerny–Turner (CT) monochromators) paired with CCD detectors are most common although Fourier transform (FT) spectrometers are also common for use with NIR lasers.

Laser Wavelengths

The name “Raman spectroscopy” typically refers to vibrational Raman using laser wavelengths that are not absorbed by the sample.

There are many other variations of Raman spectroscopy including surface-enhanced Raman, resonance Raman, tip-enhanced Raman, polarized Raman, stimulated Raman, transmission Raman, spatially offset Raman, and hyper Raman.

The post Raman Spectroscopy appeared first on Synaptek-DLS.

]]>
https://synapteklabs.com/raman-spectroscopy-has-answers/feed/ 0
What is SEM/EDX Mapping? https://synapteklabs.com/what-is-sem-edx-mapping/ https://synapteklabs.com/what-is-sem-edx-mapping/#respond Wed, 01 Jun 2022 22:39:16 +0000 https://synapteklabs.com/?p=2909 SEM/EDX Mapping? Scanning electron microscopes (SEMs) employ electron beams in order to get information from a sample at the nanoscale....

The post What is SEM/EDX Mapping? appeared first on Synaptek-DLS.

]]>
SEM/EDX Mapping?

Scanning electron microscopes (SEMs) employ electron beams in order to get information from a sample at the nanoscale.

The main type of signals that are detected are the backscattered (BSE) and secondary electrons (SE), which generate a grayscale image of the sample at very high magnifications. However, there are many other signals which can be a product of the electron-matter interaction, and these can provide additional information about the sample.

Here we will describe how energy-dispersive X-ray (EDX or EDS) analysis works on a Scanning Electron Microscope.

Explanation

Every atom has a unique number of electrons that reside under normal conditions in specific positions.

These positions belong to certain shells, which have different, discrete energies.

The generation of the X-rays in a Scanning Electron Microscope is a two-step process. With the first step, the electron beam hits the sample and transfers part of its energy to the atoms of the sample. This energy can be used by the electrons of the atoms to “jump” to an energy shell with higher energy or be knocked off from the atom.

If such a transition occurs, the electron leaves behind a hole. Holes have a positive charge and, in the second step of the process, attract the negatively-charged electrons from higher-energy shells.

When an electron from such a higher-energy shell fills the hole of the lower-energy shell, the energy difference of this transition can be released in the form of an X-ray.

This X-ray has an energy that is characteristic of the energy difference between these two shells.

It depends on the atomic number, which is a unique property of every element. In this way, X-rays are a “fingerprint” of each element and can be used to identify the type of elements that exist in a sample.

How X-ray Detection Works

Unlike BSE, SE, and TE, X-rays are electromagnetic radiation, just like light, and consist of photons.

To detect them, the latest systems use the so-called silicon-drift detectors (SDDs). These are superior to the conventional Si(Li) detectors due to higher count rates, better resolution, and faster analytical capabilities.

These detectors are placed under an angle, very close to the sample, and have the ability to measure the energy of the incoming photons that belong to the X-rays.

The higher the solid angle between the detector and the sample, the higher the X-rays’ detection probability, and therefore the likelihood of acquiring the best results.

The data that is generated by EDX analysis consists of spectra with peaks corresponding to all the different elements that are present in the sample. Every element has characteristic peaks of unique energy, all extensively documented.

Qualitative & Quantitative

Furthermore, EDX can be used for qualitative (the type of elements) as well as quantitative (the percentage of the concentration of each element of the sample) analysis.

In most SEMs, dedicated software enables auto-identification of the peaks and calculation of the atomic percentage of each element that is detected. One more advantage of the EDX technique is that it is a non-destructive characterization technique, which requires little or no sample preparation.

The post What is SEM/EDX Mapping? appeared first on Synaptek-DLS.

]]>